MassBank MassBank Search Contents Download

MassBank Record: MSBNK-MSSJ-MSJ02104

2-(octan-2-yl)tetrahydrothiophene; GC-EI-TOF; MS; POSITIVE; EI; 70 V

Mass Spectrum
Chemical Structure
Generated by the Chemistry Development Kit (http://github.com/cdk)

ACCESSION: MSBNK-MSSJ-MSJ02104
RECORD_TITLE: 2-(octan-2-yl)tetrahydrothiophene; GC-EI-TOF; MS; POSITIVE; EI; 70 V
DATE: 2023.03.27
AUTHORS: Eiyu Imai, Takemichi Nakamura, Molecular Structure Characterization Unit, RIKEN
LICENSE: CC BY
COPYRIGHT: Eiyu Imai, Takemichi Nakamura, Molecular Structure Characterization Unit, RIKEN
PUBLICATION: Yong Luo, Yuanhong Ma, Zhaomin Hou. alpha-C-H Alkylation of Methyl Sulfides with Alkenes by a Scandium Catalyst. J. Am. Chem. Soc. 2018, 140, 114-117. DOI: 10.1021/jacs.7b11245
COMMENT: This record was created by the financial support of MEXT/JSPS KAKENHI Grant Number 22HP8019 to the Mass Spectrometry Society of Japan.
COMMENT: Original ID of the mass spectral data was 3ac_i2_ei.xlsx.
COMMENT: JMS-T100GCV (JEOL, Akishima, Japan) is a reflectron time-of-flight (reTOF) mass spectrometer. Temperature of the ion-source and GC-transfer line were 200 C and 250 C, respectively. Resolving power (FWHM, nominal) was 7000.
COMMENT: EI voltage was 70 V. Typical accuracy level expected was 5 ppm. Postrun m/z adjustment with known mass was 200.15987.

CH$NAME: 2-(octan-2-yl)tetrahydrothiophene
CH$COMPOUND_CLASS: Non-natural compound
CH$FORMULA: C12H24S
CH$EXACT_MASS: 200.15987
CH$SMILES: CCCCCCC(C)C1CCCS1
CH$IUPAC: InChI=1S/C12H24S/c1-3-4-5-6-8-11(2)12-9-7-10-13-12/h11-12H,3-10H2,1-2H3
CH$LINK: INCHIKEY UROCQDUXGMFHNO-UHFFFAOYSA-N

AC$INSTRUMENT: JMS-T100GCV (JEOL, Akishima, Japan) coupled to Agilent 7890A gas chromatograph.
AC$INSTRUMENT_TYPE: GC-EI-TOF
AC$MASS_SPECTROMETRY: MS_TYPE MS
AC$MASS_SPECTROMETRY: ION_MODE POSITIVE
AC$MASS_SPECTROMETRY: IONIZATION EI
AC$CHROMATOGRAPHY: CARRIER_GAS He, flow rate 1.5 ml/min.
AC$CHROMATOGRAPHY: COLUMN_NAME HP-5 30x0.32 0.25um 19091J-413, length 30.0 m, I.D. 0.32 mm, thickness 0.25 micrometer.
AC$CHROMATOGRAPHY: COLUMN_TEMPERATURE Held at initial oven temp. 70 C for 4 min and ramped at the rate of 30 C/min to 320 C and held at the final temp. for 1.67 min.
AC$CHROMATOGRAPHY: INJECTION_TEMPERATURE 250 C
AC$CHROMATOGRAPHY: RETENTION_TIME 8.65 min.

PK$SPLASH: splash10-000i-9000000000-44927741fb2127f01b0e
PK$NUM_PEAK: 58
PK$PEAK: m/z int. rel.int.
  27.024 2.069 21
  28.006 1.6245 16
  28.031 0.29 3
  29.039 3.4651 35
  31.99 0.9486 9
  39.024 1.6828 17
  40.031 0.2796 3
  41.039 7.4421 74
  42.046 0.7543 8
  43.055 3.3197 33
  44.98 3.7081 37
  45.987 0.2612 3
  46.996 1.5371 15
  53.039 2.2441 22
  54.046 0.4679 5
  55.055 4.8909 49
  56.062 0.6437 6
  57.071 0.9589 10
  57.988 0.3439 3
  58.996 1.7047 17
  60.003 0.9595 10
  61.011 0.7501 7
  65.039 0.3758 4
  67.055 1.5829 16
  68.062 0.3502 3
  69.071 1.4191 14
  70.078 0.3304 3
  70.996 0.3269 3
  71.086 0.3205 3
  73.012 0.7005 7
  74.019 0.3094 3
  77.039 0.4084 4
  79.055 0.7287 7
  81.071 1.4403 14
  82.077 0.299 3
  83.086 0.3857 4
  85.012 2.2361 22
  86.019 5.4442 54
  87.027 100 999
  87.487 0.2812 3
  87.803 0.1736 2
  88.032 8.667 87
  88.494 0.1158 1
  89.023 4.2839 43
  90.029 0.3709 4
  91.055 0.9931 10
  95.086 0.3903 4
  101.042 0.5993 6
  104.062 0.3412 3
  115.058 2.8804 29
  116.063 0.3699 4
  117.07 0.4305 4
  129.073 0.2721 3
  143.089 1.3096 13
  157.105 1.2144 12
  200.16 7.4586 75
  201.162 0.9486 9
  202.156 0.352 4
//

system version 2.2.5
Copyright © 2006 MassBank Project; 2011 NORMAN Association; 2021 MassBank Consortium
de.NBI logo
EAWAG logo
fnr logo
IPB logo
NORMAN logo
UFZ logo
LCSB logo
HBM4EU logo
nfdi4chem logo